Safety single-phase transformers for halogen light bulbs

download PDF file
Type:
associated transformer not resistant to short circuit
Primary voltage: 0/230V
Secondary voltage: 12V (secondary voltage 24V, upon request)
Transformers to be incorporated into specific electrical equipment
Reference standards: CEI 96-7; EN 61558-2-6

PRODUCT NOT INTERESTED BY 204/108/CE NORM RELATED TO ELECTROMAGNETIC COMPATIBILITY EMISSIONS.

PART
NUMBER

POWER
[VA]

Height [mm]

Width [mm]

Depth [mm]

Weight [kg]

Mounting  A [mm]

Mounting
B [mm]

BTTMSLA004112

50

90

90

70

1.3

75

51

BTTMSLA007112

75

90

90

80

1.5

75

56

BTTMSLA010112

100

100

100

85

2.1

85

58

BTTMSLA013112

150

100

100

90

2.6

85

68

BTTMSLA016112

200

100

100

100

3.0

85

73

BTTMSLA019112

250

125

125

95

4.0

104

64

BTTMSLA022112

300

125

125

100

4.4

104

69

BTTMSLA025112

350

125

125

110

5.1

104

79

BTTMSLA028112

400

125

125

120

5.8

104

89

BTTMSLA031112

500

125

125

135

7.2

104

104

BTTMSLA034112

600

140

140

120

7.4

75

92

BTTMSLA040112

800

155

155

130

10.1

132

93

BTTMSLA046112

1000

155

155

160

13.0

132

113

Notes:
1.The total power of the transformer is supplied in relation to the highest secondary voltage.
2.Drawings, measurements and weights are indicative and can change without notice.
3.For powers and voltages not reported in the table or for special construction requirements, request the characteristics of the transformers from our technical office.