Cased single-phase transformers with connection for DIN guide

download PDF file

BTTMSDIN SINGLE-PHASE ISOLATING AND SAFETY TRANSFORMERS WITH CONNECTION FOR DIN GUIDE

Type: associated autotransformer not resistant to short circuit
Primary voltage: 0/230/400V
Secondary voltage: 12V
Class I protected transformers
IP20 Protection Degree
Transformers to be incorporated into specific electrical devices with connection on DIN guide or normal screw fastening
Reference standards: CEI 96-7; EN 61558-2-6; CEI 96-9; EN 61558-2-2

PRODUCT NOT INTERESTED BY 204/108/CE NORM RELATED TO ELECTROMAGNETIC COMPATIBILITY EMISSIONS.

PART
NUMBER

POWER
[VA]

Height
B [mm]

Width
 A [mm]

Depth
C [mm]

Weight
[kg]

Mounting
D [mm]

Mounting
E [mm]

BTTMSDIN001312

30

83

81

77

1.2

68

51

BTTMSDIN004312

50

83

81

77

1.3

68

51

BTTMSDIN007312

75

83

81

87

1.7

68

61

BTTMSDIN010312

100

101

103

89

2.3

86

62

BTTMSDIN013312

150

101

103

92

2.6

86

66

BTTMSDIN016312

200

101

103

102

3.1

86

76

BTTMSDIN019312

250

101

103

113

3.5

86

87

Notes:
1.The total power of the transformer is supplied in relation to the highest secondary voltage.
2.Drawings, measurements and weights are indicative and can change without notice.
3.For powers and voltages not reported in the table or for special construction requirements, request the characteristics of the transformers from our technical office
.

Type: associated autotransformer not resistant to short circuit.
Primary voltage: 0/230/400V
Seconady voltage: 24V (12/0/12V)
Class I protected transformers
IP20 Protection Degree
Transformers to be incorporated into specific electrical devices with connection on DIN guide or normal screw fastening
Reference standards: CEI 96-7; EN 61558-2-6; CEI 96-9; EN 61558-2-2

PRODUCT NOT INTERESTED BY 204/108/CE NORM RELATED TO ELECTROMAGNETIC COMPATIBILITY EMISSIONS.

PART
NUMBER

POWER
[VA]

Height
B [mm]

Width
 A [mm]

Depth
C [mm]

Weight
[kg]

Mountin
D [mm]

Mounting
E [mm]

BTTMSDIN001324

30

83

81

77

1.2

68

51

BTTMSDIN004324

50

83

81

77

1.3

68

51

BTTMSDIN007324

75

83

81

87

1.7

68

61

BTTMSDIN010324

100

101

103

89

2.3

86

62

BTTMSDIN013324

150

101

103

92

2.6

86

66

BTTMSDIN016324

200

101

103

102

3.1

86

76

BTTMSDIN019324

250

101

103

113

3.5

86

87

Notes:
1.
The total power of the transformer is supplied in relation to the highest secondary voltage.
2.Drawings, measurements and weights are indicative and can change without notice.
3.For powers and voltages not reported in the table or for special construction requirements, request the characteristics of the transformers from our technical office.

Type: associated autotransformer not resistant to short circuit
Primary voltage: 0/230/400V
Secondary voltage: 48V (24/0/24V)
Class I protected transformers
IP20 Protection Degree
Transformers to be incorporated into specific electrical devices with connection on DIN guide or normal screw fastening
Reference standards: CEI 96-7; EN 61558-2-6; CEI 96-9; EN 61558-2-2

PRODUCT NOT INTERESTED BY 204/108/CE NORM RELATED TO ELECTROMAGNETIC COMPATIBILITY EMISSIONS.

PART
NUMBER

POWER
[VA]

Height
B [mm]

Width
 A [mm]

Depth
C [mm]

Weight
[kg]

Mounting
D [mm]

Mounting
E [mm]

BTTMSDIN001348

30

83

81

77

1.2

68

51

BTTMSDIN004348

50

83

81

77

1.3

68

51

BTTMSDIN007348

75

83

81

87

1.7

68

61

BTTMSDIN010348

100

101

103

89

2.3

86

62

BTTMSDIN013348

150

101

103

92

2.6

86

66

BTTMSDIN016348

200

101

103

102

3.1

86

76

BTTMSDIN019348

250

101

103

113

3.5

86

87

Notes:
1.The total power of the transformer is supplied in relation to the highest secondary voltage.
2.Drawings, measurements and weights are indicative and can change without notice.
3.For powers and voltages not reported in the table or for special construction requirements, request the characteristics of the transformers from our technical office.

BTTMIDIN SINGLE-PHASE INSOLATING TRANSFORMERS WITH CONNECTION FOR DIN GUIDE

Type: associated autotransformer not resistant to short circuit
Primary voltage: 0/230/400V
Secondary voltage: 110V (55/0/55V)
Class I protected transformers
IP20 Protection Degree
Transformers to be incorporated into specific electrical devices with connection on DIN guide or normal screw fastening
Reference standards: CEI 96-8; EN 61558-2-4; CEI 96-9; EN 61558-2-2

PRODUCT NOT INTERESTED BY 204/108/CE NORM RELATED TO ELECTROMAGNETIC COMPATIBILITY EMISSIONS.

PART
NUMBER

POWER
[VA]

Height
B [mm]

Width
 A [mm]

Depth
C [mm]

Weight
[kg]

Mounting
D [mm]

Mounting
E [mm]

BTTMIDIN003311

30

83

81

77

1.2

68

51

BTTMIDIN006311

50

83

81

77

1.3

68

51

BTTMIDIN009311

75

83

81

87

1.7

68

61

BTTMIDIN012311

100

101

103

89

2.3

86

62

BTTMIDIN015311

150

101

103

92

2.6

86

66

BTTMIDIN018311

200

101

103

102

3.1

86

76

BTTMIDIN021311

250

101

103

113

3.5

86

87

Notes:
1.The total power of the transformer is supplied in relation to the highest secondary voltage.
2.Drawings, measurements and weights are indicative and can change without notice.
3.For powers and voltages not reported in the table or for special construction requirements, request the characteristics of the transformers from our technical office.

Type: associated autotransformer not resistant to short circuit
Primary voltage: 0/230/400V
Seconary voltage: 230V (115/0/115V)
Class I protected transformers
IP20 Protection Degree
Transformers to be incorporated into specific electrical devices with connection on DIN guide or normal screw fastening
Reference standards: CEI 96-8; EN 61558-2-4; CEI 96-9; EN 61558-2-2

PRODUCT NOT INTERESTED BY 204/108/CE NORM RELATED TO ELECTROMAGNETIC COMPATIBILITY EMISSIONS.

PART
NUMBER

POWER
[VA]

Height
B [mm]

Width
 A [mm]

Depth
C [mm]

Weight
[kg]

MountinG
D [mm]

Mounting
E [mm]

BTTMIDIN003323

30

83

81

77

1.2

68

51

BTTMIDIN006323

50

83

81

77

1.3

68

51

BTTMIDIN009323

75

83

81

87

1.7

68

61

BTTMIDIN012323

100

101

103

89

2.3

86

62

BTTMIDIN015323

150

101

103

92

2.6

86

66

BTTMIDIN018323

200

101

103

102

3.1

86

76

BTTMIDIN021323

250

101

103

113

3.5

86

87

Notes:
1.The total power of the transformer is supplied in relation to the highest secondary voltage.
2.Drawings, measurements and weights are indicative and can change without notice.
3.For powers and voltages not reported in the table or for special construction requirements, request the characteristics of the transformers from our technical office.